System Status Indicator LEDs

The Model 136 Monitor has two LEDs that show the operational status of the Control System. The control has two basic operating modes:

AUTO Mode

  • A green LED is lit whenever the Control is in the AUTO mode of operation. This means the automatic control of the replenisher pump(s) is governed by the Model 140/141 Control. During this operating mode, the red PUMP light will turn on and off periodically as the pump(s) are switched on and off by the control. The PUMP light indicates that AC power is sensed at the pump terminal of the Model 120 Power Module. Correct functioning of the PUMP light thus verifies correct function of the pump control chain including the pump power relay in the Power Module. Pump control functions continuously in all AUTO modes including Setup and Instant Replay.
  • MANUAL Mode

  • The green LED is off in this mode. However, the red PUMP LED is always on. In Manual mode, the replenisher pump(s) are continuously powered through the Model 120 Power Module unit allowing the operator complete control of the replenisher pump(s) power, but the alarm will sound after five minutes.